272/IN OSCILLOSCOPE : 20MHz DUAL TRACE
FEATURES
· DC- 20 Mhz Bandwidth
· 1mV/DI v Sensitivity on Both Channels
· Ch1, Ch2 ( Independent Channels ), Ch1 INVT, ADD and SUBTRACT
· X-Y Operation
· 40ns/DI v to 0.2s/DI v Time Base
· 140mm Rectangular CRT with Internal Graticule
· Triggering to 40MHz
· Z Modulation ( TTL Level)
· 8 x 10 cm Display
· TV Triggering Frame (v) & Line (H)
· Line Trigger
· Component Tester
SPECIFICATIONS
VERTICAL DEFLECTION
Deflection Coefficient ( CH1 & CH2 ) : 1mV/DI v to 20V/DI
v, 5mV/DI v to 20V/DI v in 12 calibrated steps
in 1-2-5 sequence. x5 magnification increases sensitivity to 1mV/DI v and 2mV/DI v ( LED indication ).
Accuracy : +3%
Bandwidth : DC- 20 MHz ( -3dB), dc coupled. 10Hz - 20 MHz ( -3dB),
ac coupled. DC - 28MHz ( -6dB).
Rise Time : 17.5n sec. or less.
Display Modes : Ch1, Ch2, Ch1 & CH2, Alternate or Chop mode & X-Y, CH1-Y,
CH2-X, Algebraic ADD and SUBTRACT
with CH2-INVT.
Input Impedance : 1M ohms & 25pF ( app.)
Maximum Input Voltage : 500 Volts ( dc + peak ac.)
Internal Trigger Signal : Ch1 or Ch2.
TIME BASE
Sweep Speed : 18 calibrated steps. 0.5uS/DI v to 0.2 S/DI v in 1, 2 & 5 sequence.
Sweep Magnifier : x5 Magnification extends the sweep speed to 100nS/DI v.
X5 Magnification indication with LED.
Accuracy : +3%
Variable : Uncalibrated continuously variable Control between steps, extends
fastest Sweep speed to 40nS/DI v (approx). (Uncal LED indication).
TRIGGER SYSTEM
Triggering Mode : Automatic or Normal with Level Control.
Source : CH1 / CH2 / LINE / EXT.
Slope : Positive or Negative
Coupling : ac / dc / HF reject or TV Frame / TV Line.
Trigger Seinsitivity : Internal AUTO 0.5 div 30Hz-20MHz,
NORM 0.5 div 3Hz 20MHz, External AUTO 0.8V p p 30Hz 20MHz. (TYPICAL 40MHz)
HORIZONTAL DEFLECTION
Deflection Coefficient : Same as CH2.
Bandwidth : DC 2.5 MHz (-3dB). Phase shift <3 deg. At 60KHz.
Input Impedance : 1M ohms and 25pF (approx.)
COMPONENT TESTER
Component Tester allows V- I characteristics of a Device Under Test ( D. U. T. )
Test Voltage : 8.6 V r. m. s.
Test Current : 28 mA max.
Test Frequency : 50Hz or 60Hz (MAINS).
GENERAL INFORMATION
Cathode Ray Tube : 140mm Rectangular screen, Internal Graticule, 8 x 10 cm,
P43 phosphor.
Accelerating potential: 2KV.
Trace Rotation : Front Panel control, allows + 5°of trace adjustment.
Z Modulation : TTL level.
Calibrator : Provides 0.2V 1%, 1KHz (approx.) Squarewave output for probe
compensation.
Power Requirement : 230V AC 10%, 47 65Hz, 40VA or 115V AC 10% (on request).
Dimensions : 165 (H) x 320 (W) x 420 (D) mm approx
Weight : 8.0 Kgs. Approx.
Accessories : Manual with Circuit 1 No.
Diagrams : BNC Crocodile Cable - 1 No.
Component Tester Lead - 1 No.
Optional : High impedance switch probe
with x 1 or x 10 Attenuation, trolley.
Environmental Specifications :
Normal : 10 deg C 40 deg C RH 85%
Operational : 0 deg C to 50 deg C RH 85%
|